Thermo Scientific™ Nalgene™ Rapid-Flow™ Sterile Disposable Filter Units with PES, CN, SFCA or Nylon Membranes
Greener Choice Product
This product offers one or more environmental benefits itemized in the U.S. FTC “Green Guides.”
Learn More About the Greener Choice Program

This product offers one or more environmental benefits itemized in the U.S. FTC “Green Guides.”
Learn More About the Greener Choice Program
Increase filtration efficiency. PES membranes and exclusive Rapid-Flow design provide fast flow rates and high throughput while defending against cell culture contamination.

Disposable | Single-use |
---|---|
Type | Filter Unit |
No. per Pack | 12 |
Fit for Purpose | Sterile |
Sterility | Sterile |
Fisherbrand™ Nylon Membrane Filter
Naturally hydrophilic membrane designed to wet out evenly and retain its superior strength during use in general filtration or medical assays.

Wettability | Yes |
---|---|
Type | Plain Disc |
Color | White |
Quantity | 100 Pack |
Material | Nylon |
Filter Type | Microfilter |
Hydrophobicity | Hydrophilic |
For Use With (Application) | Sterilizing filtration of aqueous solutions, organic solvents, Bacterial and particles removal (blood Glucose, Serum Cholesterol, drugs) |
Autoclavable | Autoclavable |
Sterility | Non-sterile |
Fisherbrand™ Grade 600 Cellulose General Purpose Filter Paper: Sheets
Used in schools and as bench protective paper. Fisherbrand Grade 600 Cellulose General Purpose Filter Paper is economical.

Thickness (Metric) | 0.15 mm |
---|---|
Pore Size | 10 to 20 μm |
Particle Retention | 10 to 20 μm |
Grade | 600 |
Material | Cellulose |
For Use With (Application) | Economical filter Paper used in schools and as bench protective Paper |
Fisherbrand™ PTFE Filter Membranes
Fisherbrand™ PTFE membrane is hydrophobic filter made of polytetra-fluorethylene laminated with PP layer.

Thickness (Metric) | 0.16 mm |
---|---|
Wettability | Yes |
Type | Plain Disc |
Color | White |
Quantity | 100 Pack |
Material | PTFE |
Hydrophobicity | Hydrophobic |
For Use With (Application) | Sterilizing filtration of gas samples, clarification and filtration of pure solvents, aerosol samplings, filtration of strong Acids and chemical aggressive solutions, venting applications (hospital air conditioning, tank fermentation in microelectronic) |
Fisherbrand™ Mixed Cellulose Ester Membranes Sterile Filter
Fisherbrand™ Mixed Celluloses Esters Membranes Sterile Filters are composed of cellulose acetate and cellulose nitrate.

Wettability | Yes |
---|---|
Type | Gridded Disc |
Diameter (Metric) | 47 mm |
Quantity | 100/Pk. |
Material | MCE |
Hydrophobicity | Hydrophilic |
For Use With (Application) | Microdialysis of DNA and Proteins, clarification of aqueous solutions during microbiological analysis, identification of Nucleic Acids |
Sterility | Sterile |
Fisherbrand™ Mixed Celluloses Esters Membranes Non-sterile Filter
Fisherbrand™ Mixed Celluloses Esters Membranes Non-sterile Filters are composed of cellulose acetate and cellulose nitrate.

Wettability | Yes |
---|---|
Type | Plain Disc |
Color | White |
Quantity | 100 Pack |
Material | MCE |
Hydrophobicity | Hydrophilic |
For Use With (Application) | Microdialysis of DNA and Proteins, clarification of aqueous solutions during microbiological analysis, identification of Nucleic Acids |
Sterility | Non-sterile |
Cytiva Whatman™ Binder-Free Glass Microfiber Filters, Grade GF/A
Combines high loading capacity with fine particle retention. Whatman™ Binder-Free Glass Microfiber Filters, Grade GF/A are ideal for gravimetric determination of airborne particulates, stack sampling and absorption methods of air pollution monitoring.

Particle Retention | 1.6 μm |
---|---|
Temperature (English) Max. | 932°F |
Shape | Circle |
Description | GE’s Whatman Grade GF/A glass microfiber filters feature fine retention. GF/A filters are suitable for water quality parameter measurement and air filtration applications. |
Temperature (Metric) Max | 500°C |
Quantity | 100 Pieces |
Grade | Grade GF/A |
Material | Borosilicate Glass |
For Use With (Application) | Used for high-efficiency general purpose laboratory filtration, including water pollution monitoring of effluents, for filtration of water, foodstuff analyses, protein filtration, and radioimmunoassay of weak β emitters. |
Thickness (Metric) | 260 μm |
Flow Rate | 13 sec./100mL |
Type | Fine Retention Filter |
Format | Disc |
Thickness (English) | 0.01 in. |
Waterflow Rate | 143 mL/min |
Sartorius Cellulose Acetate Membrane Filters
Combines high flow rates and thermal stability with very low adsorption characteristics. Sartorius Cellulose Acetate Membrane Filters are excellently suited for use in pressure filtration devices. Non-sterile filters in a variety of diameters and pore sizes are bulk-packed to save money and space.

Thickness (Metric) | 120 μm |
---|---|
Disposable | Single-use |
Type | Membrane Filter |
Format | Disc |
Material (Membrane) | Cellulose Acetate |
Color | White |
Material | Cellulose Acetate |
Hydrophobicity | Hydrophilic |
For Use With (Application) | For use in pressure filtration devices; Sterile filtration of solution. |
Autoclavable | Autoclavable |
Sterility | Non-sterile |
Cytiva Whatman™ Qualitative Filter Paper: Grade 595 ½ Pleated Circles
Pleated to save time and achieve optimal fit in conical filter funnels. Whatman™ Qualitative Filter Paper: Grade 595 ½ Pleated Circles provide extra surface area to increase total loading capacity.

Thickness (Metric) | 150 μm |
---|---|
Pore Size | 7 μm |
Flow Rate | Medium fast |
Particle Retention | 7 μm |
Quantity | 100 Pk. |
Grade | Grade 595 ½ |
Material | Cellulose |
Filtration Speed | Approx. 80 s |
For Use With (Application) | A prepleated filter used for many routine analytical applications in different industries (e.g., particle separation from food extracts or filtration of solids from digested environmental samples, e.g., for ICP/AAS analysis). |
Cytiva Whatman™ Nuclepore™ Hydrophilic Membrane
A highly defined pore size cutoff in the sub-micron range enables particle deformity measurements, and the capture of extremely small particles

Type | Track Etched Hydrophilic Membrane Filters |
---|---|
Shape | Circle |
Hydrophobicity | Hydrophilic |
For Use With (Application) | Bioassays, Cell Biology and Environment Analysis |
Membrane Type | Polycarbonate Film Track-Etched (PFTE) |
Sartorius Minisart™ NML Syringe Filters, Sterile
SureTRACE
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More

Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Provides fast and reliable filtration of small to medium volumes, complete with ready-to-connect filter units. Sartorius Minisart™ NML Syringe Filters, Sterile eliminate time consuming preparatory work, such as changing out the filter and cleaning the filtration system.

Disposable | Single-use |
---|---|
For Use With (Equipment) | Syringe |
Diameter (Metric) | 28 mm |
Inlet Style | Female Luer Lock |
Housing Material | Meta acrylate butadiene styrene polymerisate (MBS) |
Volume (Metric) | 200 mL |
Sample Volume | 1 to 200 mL |
Filter Type | Syringe Filter |
For Use With (Application) | Preparation of aqueous liquids |
Hold up Volume (After Air Purge) | 0.15 mL |
Sterility | Sterile |
Filtration Area | 6.2 cm2 |
Sartorius™ Smooth Filter Paper Discs, Grade 3-HW
SureTRACE
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More

Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Use for routine qualitative analyses and technical applications. Sartorius™ Smooth Filter Paper Discs, Grade 3-HW can be used for pressure and vacuum filtration. Ultra-pure filters are available in filter disc format in a variety of diameters.

Thickness (Metric) | 0.14 mm |
---|---|
Particle Retention | 8 to 12 μm |
Type | Qualitative Filter Paper |
Format | Disc |
Grade | 3HW |
Material | Cotton Linters, Refined Pulp |
Filtration Speed | 20μm/sec. |
For Use With (Application) | For qualitative-technical analyses, used for routine analyses like clarification, determination of substances, but also as discs with a center hole for technical applications |
Cytiva (formerly Pall Lab) Supor™ 200 Membrane Disc Filters
Membranes are used to sterilize liquid reagents, remove particulate contamination, and clarify solutions prior to further processing.

Thickness (Metric) | 145 μm |
---|---|
Pore Size | 0.2 μm |
Material | PES |
Sterility | Non-sterile |
Cytiva (formerly Pall Lab) Supor™ 450 Membrane Disc Filters
High flow rate membrane optimized for biological, pharmaceutical, and sterilizing filtration requirements.

Thickness (Metric) | 140 μm |
---|---|
Pore Size | 0.45 μm |
Material | PES |
Sterility | Non-sterile |
Cytiva Sentino™ GN-6 Membrane