Flow Cytometry Compensation, Counting and Calibration
Flow Cytometry Compensation, Counting and Calibration
- (6)
- (1)
- (5)
- (4)
- (7)
- (4)
- (16)
- (1)
- (1)
- (2)
- (2)
- (2)
- (1)
- (1)
- (3)
- (1)
- (1)
- (1)
- (3)
- (2)
- (1)
- (4)
- (5)
- (5)
- (1)
- (2)
- (2)
- (1)
- (6)
- (1)
- (3)
- (3)
- (1)
- (1)
- (1)
- (1)
- (2)
- (7)
- (31)
- (24)
- (12)
- (2)
- (3)
- (1)
- (2)
- (8)
Filtered Search Results
Molecular Probes™ Flow Cytometry Size Calibration Kit (nonfluorescent microspheres)
Flow Cytometry Size Calibration Kit (nonfluorescent microspheres)
Invitrogen™ Cell Sorting Set-up Beads (for blue lasers)
Approximate the size, emission wavelength, and intensity of many biological samples, and so can be used to calibrate a flow cytometer’s cell sorting system, including laser source, optics, and stream flow.
Includes | Water insoluble fluorescent dyes |
---|---|
Content And Storage | 4°C |
Format | Liquid |
Product Type | Fluorescent Particles |
Color | Clear |
Volume (Metric) | 2 mL |
Material | Polystyrene |
Concentration | 1% |
Certifications/Compliance | RUO |
For Use With (Application) | Flow Cytometry Calibration and Alignment |
Invitrogen™ UltraComp eBeads™ Compensation Beads
Designed for use in compensation with all fluorochromes excited by ultraviolet, violet, blue, green, yellow-green, and red lasers. UltraComp eBeads™ react with antibodies of mouse, rat, and hamster origin, and are immunoglobulin light chain-independent. 1 drop (50μL)/test.
For Use With (Equipment) | Flow Cytometer |
---|---|
Product Type | Compensation Beads |
Product Line | eBeads™ |
Molecular Probes™ CountBright™ Absolute Counting Beads, for flow cytometry
CountBright™ Absolute Counting Beads, for flow cytometry
Invitrogen™ ArC™ Amine Reactive Compensation Bead Kit (for use with LIVE/DEAD™ Fixable dead cell stain kits)
ArC™ Amine Reactive Compensation Bead Kit (for use with LIVE/DEAD™ Fixable dead cell stain kits)
Shipping Condition | Room Temperature |
---|---|
Format | Tube |
For Use With (Equipment) | Flow Cytometer |
Product Type | Compensation Beads |
Diameter (Metric) | 6 μm |
Stain Configuration | Surface |
Quantity | 1 Kit |
Detection Method | Fluorescence |
Invitrogen™ AbC™ Total Antibody Compensation Bead Kit
Provides a consistent, accurate, and simple-to-use technique for the setting of flow cytometry compensation when using fluorochrome-conjugated mouse, rat, hamster, or rabbit antibodies with any laser in flow cytometry.
Shipping Condition | Room Temperature |
---|---|
Content And Storage | Contains 1 vial AbC™ Total Compensation capture beads and 1 vial of negative beads. |
Format | Tube |
For Use With (Equipment) | Flow Cytometer |
Product Type | Compensation Beads |
Diameter (Metric) | 6 μm |
Excitation Wavelength Range | any lasers (UV to 633/635) |
Product Line | AbC™ |
Detection Method | Fluorescence |
Invitrogen™ BrightComp eBeads™ Compensation Bead Kits
BrightComp eBeads compensation beads provide a consistent, accurate, and simple-to-use technique for setting flow cytometry compensation when using fluorescent protein-expressing samples.
Product Type | Compensation Beads |
---|---|
For Use With (Application) | Flow Cytometry |
Invitrogen™ CountBright™ Plus Absolute Counting Beads
Calibrated suspension of ∼4 μm beads that encapsulate dyes that are excitable across a wide range of UV-IR wavelengths and brightly fluoresce in the emission range of 385-860 nm.
Shipping Condition | Room Temperature |
---|---|
Content And Storage | Store at room temperature. |
Product Type | Fixation Medium |
Reagent Type | Fixation Reagent |
Invitrogen™ eBioscience™ Foxp3 / Transcription Factor Staining Buffer Set
Formulated and optimized for staining with antibodies against transcription factors and nuclear proteins (e.g. Foxp3 and Ki-67), cytokines and chemokines
Molecular Probes™ Alignflow™ Flow Cytometry Alignment Beads for Blue Lasers, 6.0 μm
Alignflow™ Flow Cytometry Alignment Beads for Blue Lasers, 6.0 μm
Molecular Probes™ Alignflow™ Flow Cytometry Alignment Beads for UV Lasers, 6.0 μm
Alignflow™ Flow Cytometry Alignment Beads for UV Lasers, 6.0 μm
Invitrogen™ eBioscience™ Mouse Intracellular (nuclear/transcription factor) Protein Flow Cytometry Workflow Kit
The eBioscience™ Mouse Intracellular (nuclear/transcription factor) Protein Flow Cytometry Workflow Kit contains all of the normal buffers, blockers, and beads needed to complete a standard flow cytometry experiment for staining intracellular nuclear and transcription factor targets in human cell suspensions.