Filtered Search Results
Cole-Parmer™ Jenway™ 74 Series Visible and UV/Visible Scanning Spectrophotometers with CPLive™ Connectivity
Get cloud-based secure storage of your results and protocols with Jenway 74 Series Visible and UV/Visible Scanning Spectrophotometers with CPLive Connectivity
Connections | 2 x USB-A, 1 x USB-B, Ethernet RJ45 |
---|---|
Photometric Range | 0 to 199.9 %T |
Wavelength Repeatability | ± 0.5 nm |
Spectral Bandwidth | 5 nm |
Absorbance Range | −0.3 to +2.5 A |
Concentration | -300 to 9999 |
Includes | 10GB memory |
Detector Type | Silicon Photodiode |
Type | Spectrophotometer |
Dimensions (L x W x H) | 50 x 28 x 15.6 cm |
Wavelength Accuracy | ±2 nm |
Voltage | 100/240 V |
Absorbance Accuracy | ±0.01 A at 1.000 Absorbance |
Certifications/Compliance | CE |
Optical Design | Single |
Hertz | 50/60 Hz |
Display | Touchscreen |
Jenway™ Genova Nano Micro-volume Spectrophotometer
Measures small sample volumes as low as 0.5μL with a high degree of accuracy, reproducibility and speed. Jenway™ Genova Nano Micro-volume Spectrophotometer is ideal for DNA, RNA and protein measurements and can detect DNA concentrations as low as 2ng/μL.
Implen™ NanoPhotometer™ N60 Micro-Volume UV-VIS Spectrophotometer
The Implen NanoPhotometer™ N60 UV/Vis spectrophotometer for NanoVolume applications. Quantify DNA, RNA, proteins and scan other samples within seconds.
Connections | 2x USB A, USB B, HDMI, Ethernet, WiFi |
---|---|
Processor | Linux based NPOS |
Spectral Bandwidth | <1.8 nm |
Languages | English, French, German, Spanish, Portuguese, Russian, Chinese, Japanese |
Absorbance Range | 0.02 to 330 A |
Pathlength | 0.67 and 0.07 mm |
For Use With (Application) | Nucleic Acids, Protein UV, Protein Assays, Kinetics, OD600, Wavelength, Wavescan, Standard Curve, Absorbance Ratio, Concentration, Custom |
Light Source | Xenon Flash |
Measurement Time | 2.5 to 4.0 sec |
Sample Volume (Metric) | 0.3 to 2 μL |
Detector Type | 3648-element CCD Array |
Dimensions (L x W x H) | 20 x 20 x 12 cm |
Wavelength Accuracy | ± 0.75 nm |
No. of Samples | 1 |
System Requirements | Windows 7, 8, 10 (32 & 64 bit); OS X, iOS; Android OS |
Voltage | 90/250 V |
Stray Light | < 0.5% @ 240 nm using NaI |
Absorbance Accuracy | < 1.75% at 0.7 A at 280 nm of the reading |
Wavelength Range | 200 to 900 nm |
Measurement Range | 1 to 16,500 ng/μL |
Display | 7 in. Glove Compatible Touchscreen, 1024 x 600 pixels |
Implen™ NanoPhotometer™ NP80 Nano-Volume and Cuvette UV-VIS Spectrophotometer
The Implen NanoPhotometer™ NP80 UV/Vis spectrophotometer for NanoVolume and cuvette applications. Quantify DNA, RNA, proteins and scan other samples within seconds.
Connections | 2x USB A, USB B, Ethernet, WiFi |
---|---|
Operating Temperature | 37 °C ± 0.5 °C Cuvette |
Beam Center Height | 8.5 mm |
Processor | Linux based NPOS |
Spectral Bandwidth | <1.8 nm |
Languages | English, French, German, Spanish, Portuguese, Russian, Chinese, Japanese |
Absorbance Range | 0.02 to 330 A NanoVolume, 0 to 2.6 A Cuvette |
Pathlength | 0.67 and 0.07 mm |
For Use With (Application) | Nucleic Acids, Protein UV, Protein Assays, Kinetics, OD600, Wavelength, Wavescan, Standard Curve, Absorbance Ratio, Concentration, Custom |
Light Source | Xenon Flash |
Measurement Time | 2.5 to 4.0 sec |
Sample Volume (Metric) | 0.3 to 2 μL |
Detector Type | 3648-element CCD Array |
Dimensions (L x W x H) | 20 x 20 x 12 cm |
Wavelength Accuracy | ± 0.75 nm |
No. of Samples | 1 |
System Requirements | Windows 7, 8, 10 (32 & 64 bit); OS X, iOS; Android OS |
Voltage | 90/250 V |
Stray Light | < 0.5% @ 240 nm using NaI |
Absorbance Accuracy | < 1.75% at 0.7 A at 280 nm of the reading |
Wavelength Range | 200 to 900 nm |
Measurement Range | 1 to 16,500 ng/μL |
Display | 7 in. Glove Compatible Touchscreen, 1024 x 600 pixels |
Implen™ NanoPhotometer™ N120 Multichannel Micro-Volume UV-VIS Spectrophotometer
The Implen NanoPhotometer™ N120 scans up to 12 samples in just 20 seconds. Quantifying DNA, RNA and proteins has never been faster. Intuitive touchscreen operation, small footprint and network integration for convenient lab bench operation. Recalibration-free patented technology Made in Germany.
Processor | Linux based NPOS |
---|---|
Spectral Bandwidth | <2.5 nm |
Languages | English, French, German, Spanish, Portuguese, Russian, Chinese, Japanese |
Absorbance Range | 0.04 to 160 A |
Pathlength | 1 and 0.125 mm |
For Use With (Application) | Nucleic Acids, Protein UV, Protein Assays, Kinetics, OD600, Wavelength, Wavescan, Standard Curve, Absorbance Ratio, Concentration, Custom |
Light Source | Xenon Flash |
Measurement Time | 1.7 - 2.5 seconds |
Sample Volume (Metric) | 2 to 3.5 μL |
Detector Type | 3648-element CCD Array |
Dimensions (L x W x H) | 20 x 20 x 12 cm |
Wavelength Accuracy | ± 0.75 nm |
No. of Samples | 1 to 12 |
System Requirements | Windows 7, 8, 10 (32 & 64 bit); OS X, iOS; Android OS |
Voltage | 90/250 V |
Stray Light | < 1% @ 240 nm using NaI |
Wavelength Range | 200 to 900 nm |
Display | 7 in. Glove Compatible Touchscreen, 1024 x 600 pixels |
Implen™ NanoPhotometer™ N50-Touch Micro-Volume UV-VIS Spectrophotometer
The Implen NanoPhotometer™ N50 UV/Vis spectrophotometer for NanoVolume applications. Quantify DNA, RNA, proteins and scan other samples within seconds. Intuitive touchscreen operation, small footprint and network integration for convenient lab bench operation.
Biochrom Ultrospec™ 7000 UV-Vis Spectrophotometer
The Ultrospec 7000 is a high performance standalone double-beam, UV-Visible spectrophotometer developed to meet the day-to-day needs of the busy laboratory doing many different applications. Engineered for robust, lower cost operation with minimal maintenance requirements.
Biochrom Ultrospec 9000 Spectrophotometer UV-Vis Spectrophotometer with Bluetooth
The Ultrospec 9000 is a high performance standalone double-beam, variable bandwidth UV-Visible spectrophotometer designed for operation in regulated laboratories. Bluetooth capabilities.
Biochrom Ultrospec 7000 Spectrophotometer UV-Vis Spectrophotometer with Bluetooth
The Ultrospec 7000 is a high performance standalone double-beam, UV-Visible spectrophotometer developed to meet the day-to-day needs of the busy laboratory doing many different applications. Engineered for robust, lower cost operation with minimal maintenance requirements. Bluetooth capabilities.
Cytiva Ultrospec™ 8000 Spectrophotometer
Features multiuser capablity with secure login to protect methods.
Connections | USB cable, USB memory stick |
---|---|
Height (Metric) | 457 mm |
Electrical Requirements | 30 VAC |
Warranty | 2 years instrument, 1 year lamp |
Width (English) | 20.98 in. |
Spectral Bandwidth | 1 nm |
For Use With (Application) | Designed to Meet The Requirements of Critical Analysis and Users in Pharmacopoeia Research Environments |
Wavelength Accuracy | ±0.3 nm |
Voltage | 90/250 V |
Weight (English) | 39.68 lb. |
Certifications/Compliance | 21 CFR part 11 |
Wavelength Range | 190 to 1100 nm |
Weight (Metric) | <18 kg |
Height (English) | 17.99 in. |
Product Line | Ultrospec 8000 |
Display | Touchscreen |
Biochrom NanoVue Plus Micro-Volume UV-Vis Spectrophotometer with Printer
Easy to use instrument designed for reliable measurements of nucleic acids and proteins. Includes printer and operates without the use of a PC.
Biochrom Ultrospec™ 7000 PC UV-Vis Spectrophotometer
The Ultrospec 7000PC is a high performance double-beam, UV-Visible spectrophotometer developed to meet the day-to-day needs of the busy laboratory doing many different applications. Engineered for robust, lower cost operation with minimal maintenance requirements. PC operated, not included.
Biochrom Ultrospec™ 8000 Dual Beam UV/Visible Spectrophotometer
Designed to meet the requirements of critical analysis and users in Pharmacopoeia research environments
Biochrom NanoVue Plus Spectrophotometer
Easy to use instrument designed for reliable measurements of nucleic acids and proteins. Operates without the use of a PC.
Biochrom Ultrospec™ 9000 PC UV-Vis Spectrophotometer
Ultrospec 9000PC is a high performance double-beam, variable bandwidth UV-Visible spectrophotometer designed for operation in regulated laboratories. PC operated, not included.