Spectrophotometry
Spectrophotometry
Filtered Search Results
Thermo Scientific™ GENESYS™ 30 Visible Spectrophotometer
Perform both basic and complex analyses with the Thermo Scientific™ GENESYS™ 30 Visible Spectrophotometer, an intuitive, reliable solution for education or in the lab.
Photometric Accuracy | ±0.002 A (0 to 0.3 A), 0.5% of ABS reading (0.301 A to 2.5 A) |
---|---|
Connections | USB-A, USB-B |
Scan Speed | Automatic – up to 1200 nm/min. |
Printer Included | Thermal printer accessory with 80 mm width paper |
Noise | ≤0.001A at 0A |
Languages | English, French, German, Spanish, Italian, Portuguese, Russian, Chinese, Japanese, Korean, Thai, Arabic |
Detector Type | Silicon Photodiode |
Compartments | Accessible from top, front or side Able to accommodate cells up to 100mm pathlength Available accessory for test-tubes up to 25mm diameter and 150mm height Removable, washable sample compartment liner with magnetic placement and hold-down |
Stray Light | <0.1%T at 340 nm and 400 nm Measured using glass cutoff filters or NaNO2 at 340 nm |
Optical Design | Single Beam |
Photometric Repeatability | ± 0.002 A Measured at 1.0 A at 546 nm |
Weight (Metric) | 7.5 kg |
Wavelength Data Interval | 1 nm |
Electrical Requirements | External AC to DC converter. Voltage and Frequency (Hz) selected automatically, 100/250 V, 50/60 Hz |
Warranty | 2 years standard with 1 year extension upon registration of the instrument with Thermo Fisher Scientific within 6 months of purchase |
Photometric Range | -3A to +3A |
Wavelength Repeatability | < ±1 nm |
Spectral Bandwidth | 5 nm |
Baseline Flatness | <0.003 A, 325 to 1000 nm, smoothed |
Photometric Display | -3A to +3A, 0 to 200 000 %T, 0 to 9 999 999 C |
Type | Visible Spectrophotometer |
Dimensions (L x W x H) | 35.5x 38.5x 19.5 cm |
Wavelength Accuracy | ±2 nm |
Lamp Life | 1000 hrs. |
Keypad | Tactile rubber 23 keys with numeric keypad |
Drift | <0.002 A/hr. (At 500 nm after 2 hr. warmup.) Typical <0.004 A/hr. after 1 hr. warmup |
Wavelength Range | 325 to 1100 nm |
Product Line | GENESYS 30 |
Display | 5 in. 32-bit Color Display, 800 x 480 pixels |
Thermo Scientific™ GENESYS™ 40/50 Vis/UV-Vis Spectrophotometers
For teaching labs or quality control experts who require ruggedness, ease-of-use and software capability in UV-Vis spectrophotometry.
Thermo Scientific™ SPECTRONIC™ 200 Spectrophotometer
Thermo Scientific™ SPECTRONIC™ 200 is the standard for rugged, simple-to-use visible spectrophotometers for teaching and routine applications.
Thermo Scientific™ SPECTRONIC 200™ Spectrophotometer
Thermo Scientific™ SPECTRONIC™ 200 is the new standard for rugged, simple-to-use visible spectrophotometers for teaching and routine applications.
Connections | USB-B for connection to a remote computer USB-A for connection to a printer or USB memory device |
---|---|
Width (English) | 15.3 in. |
Printer Included | External printer support: Epson TM-T88V |
Languages | English, French, German, Spanish, Italian, Chinese, Japanese, Korean, Thai |
Photometric Readout | ABS, %T, Concentration (standard or custom units) |
Light Source | Tungsten Halogen |
Width (Metric) | 39 cm |
Includes | Two Cuvet Racks; Ten 1cm plastic cuvets |
Detector Type | 2048-element CCD |
Compartments | Removable, washable sample compartment |
Stray Light | <0.2%T (with SPECTRONIC standard SRM 400 filter) |
Optical Design | Single Beam |
Photometric Repeatability | ±0.03 A at 0.3 A |
Weight (Metric) | 5.2 kg |
Height (English) | 3.6 in. |
Height (Metric) | 16 cm |
Electrical Requirements | Selected automatically, 100/240 V, 50/60Hz |
Depth (English) | 11.8 in. |
Photometric Range | -0.3 to 2.5Å |
Wavelength Repeatability | ±1nm |
Data Interval for Scanning | 1 nm on-board, 0.5 nm under computer control |
Spectral Bandwidth | <4 nm |
Photometric Display | -0.3A - 2.5A; 0 - 125%T |
Wavelength Accuracy | ±2 nm |
Lamp Life | 1000 hrs. |
Depth (Metric) | 30 cm |
Keypad | Sealed tactile rubber |
Container Type | Single cell holder for square cuvettes and for test tubes |
Weight (English) | 9.7 lb. |
Interface | USB-B; USB-A |
Wavelength Range | 340 to 1000 nm |
Display | 3.5 in. Color Graphic TFT LCD |
Cole-Parmer™ Jenway™ 74 Series Visible and UV/Visible Scanning Spectrophotometers with CPLive™ Connectivity
Get cloud-based secure storage of your results and protocols with Jenway 74 Series Visible and UV/Visible Scanning Spectrophotometers with CPLive Connectivity
Connections | 2 x USB-A, 1 x USB-B, Ethernet RJ45 |
---|---|
Photometric Range | 0 to 199.9 %T |
Wavelength Repeatability | ± 0.5 nm |
Spectral Bandwidth | 5 nm |
Absorbance Range | -0.3 to +2.5 A |
Pathlength | 10 to 100 mm |
Concentration | -300 to 9999 |
Includes | 10GB memory |
Detector Type | Silicon Photodiode |
Type | Spectrophotometer |
Dimensions (L x W x H) | 50 x 28 x 15.6 cm |
Wavelength Accuracy | ± 2 nm |
Photometric Accuracy Including Standard Tolerance | ±1%T |
Voltage | 100/240 V |
Absorbance Accuracy | ±0.01 A at 1.000 A |
Certifications/Compliance | CE |
Optical Design | Single |
Hertz | 50/60 Hz |
Display | Touchscreen |
Thermo Scientific™ GENESYS™ 140/150 Vis/UV-Vis Spectrophotometers
Get the most for your QA/QC or teaching lab with a rugged, network ready spectrophotometer designed for repetitive measurements and ease of use.
Biochrom Ultrospec™ 30 Cell Density Meter
Ultrospec™ 30 Cell Density Meter for measuring density of bacteria and yeast cells in suspension.
Biochrom BioDrop Duo+
The BioDrop Duo+ is a Micro-Volume UV/Vis spectrophotometer with pre-programmed life science methods and general spectrophotometric capabilities. This 2-in-1 instrument will fulfill the needs of the most demanding laboratories.
Shape | Round |
---|---|
Wavelength Repeatability | ±1 nm |
Spectral Bandwidth | 5 nm |
Languages | English, French, German, Spanish, Italian, Chinese, Japanese |
Pathlength | 10 mm + 0.5 mm |
For Use With (Application) | General Spectrophotometry and Life Science Methodology |
Light Source | Xenon Flash |
Measurement Time | >4 Seconds |
Sample Volume (Metric) | Minimum 0.5 μL |
Type | Microvolume UV-Vis Spectrophotometer |
Dimensions (L x W x H) | 280 x 410 x 190 mm |
Wavelength Accuracy | ±2 nm |
Voltage | 120/240 V |
Stray Light | <0.5 %T at 220 nm NaI; <0.5 %T (at 340 nm NaNO2) |
Weight (English) | 7.9 lb. |
Photometric Repeatability | ±0.003 A (0 to 0.5 A); ±0.007 A (0.5 to 1.0 A) |
Interface | Touch Screen Display (Color), USB Port |
Wavelength Range | 190 to 1100 nm |
Weight (Metric) | 3.6 kg |
Product Line | BioDrop Duo+ |
Display | Color Touchscreen |
Biochrom Biowave 3+
The Biowave 3+ offers all the capabilities of a research grade UV/Vis spectrophotometer. Expect exceptionally high resolution with the 3 nm bandwidth. The robust design and reasonable cost make it great for students.
Height (Metric) | 100 mm |
---|---|
Beam Center Height | 15 mm |
Shape | Round |
Depth (English) | 15.3 in. |
Width (English) | 10 in. |
Photometric Linearity | ±1.3% or ±0.008 A (Whichever is Greater at 546 nm) |
Noise | ±0.005 peak to peak ±0.002 RMS |
Monochromator | Flat Grating |
Photometric Range | -0.3 to 2.5 A, 0.3 to 199 %T |
Wavelength Repeatability | ±1 nm |
Spectral Bandwidth | 3 nm |
Languages | English, French, German, Spanish, Italian, Chinese, Japanese |
Light Source | Xenon Flash |
Width (Metric) | 260 mm |
Detector Type | Twin CMOS Array |
Wavelength Accuracy | ±2 nm |
Depth (Metric) | 390 mm |
Voltage | 100/115/220/230 V |
Stray Light | <0.5 %T 340 nm |
Weight (English) | 6.6 lb. |
Photometric Repeatability | ±0.002 A to 0.5 A (at 546 nm) |
Wavelength Range | 190 to 1100 nm |
Weight (Metric) | 3 kg |
Height (English) | 3.9 in. |
Display | Graphic LCD |
Jenway™ 6305 UV/Visible Spectrophotometer
Suitable for applications that require measurements in the UV-visible range. Jenway™ 6305 UV/Visible Spectrophotometer includes multi-parameter displays, full interfacing capability, and versatile sampling accessories.
Lovibond™ PFXi-195/1 Colorimeter: Liquid Chemicals and Industrial Oils
Accurate, efficient automatic colorimeter for objective color measurement of transparent liquids
Lovibond™ Colorimeter Tablet Reagent: DPD No. 1
Use with MC500, MD600, SC450, MD100 colorimeters, SP600 spectrophotometer, Pool Control 9, AquaPRO3 Pool and AquaPRO6 Pool photometers and Scuba IIElectronic Pool Tester
Lovibond™ Colorimeter Tablet Reagent: DPD No. 3
For use with MC500, MD600, SC450, MD100 colorimeters, SP600 spectrophotometer, Pool Control 9, AquaPRO3 Pool and AquaPRO6 Pool photometers and Scuba II Electronic Pool Tester.
Lovibond™ MD600 Handheld Water Quality Colorimeter
Rugged, waterproof multi-parameter colorimeters for laboratory and field testing
Thermo Scientific™ Orion™ AquaMate Vis and UV-Vis Spectrophotometers
Optimized for your water analysis needs AquaMate 7100 Vis and AquaMate 8100 UV-Vis Spectrophotometers provide fast and reliable results
Photometric Accuracy | ±0.002 A at 0.5 A, ±0.004 A at 1.0 A, ±0.008 A at 2.0 A |
---|---|
Connections | Single USB-A Export data to network or PC via USB, Ethernet, or Wi-Fi USB adaptor, available Print via USB, Ethernet or Wi-Fi USB adaptor available |
Height (Metric) | 19.5 cm |
Electrical Requirements | External AC to DC converter. Voltage and Frequency (Hz) selected automatically, 100/240 V, 50/60 Hz |
Warranty | 1 Year |
Length (Metric) | 35.5 cm |
Noise | (RMS at 500 nm 60 consecutive measurements) ≤0.00020A at 0A at 260 and 500 nm ≤0.00030A at 1A at 260 and 500 nm ≤0.00040A at 2A at 260 and 500 nm |
Wavelength Repeatability | < ±0.2 nm |
For Use With (Application) | Water and Waste Water Analysis |
Width (Metric) | 38.5 cm |
Detector Type | Dual Silicon Photodiodes |
Dimensions (L x W x H) | 35.5 x 38.5 x 19.5 cm |
Wavelength Accuracy | ±0.5 nm |
Depth (Metric) | 35.5 cm |
Compartments | Accessible from top, front or side Able to accommodate cells up to 100 mm cells Available accessory for test tubes up to 25 mm diameter and 150 mm height Removable, washable sample compartment liner with magnetic placement and hold-down |
Keypad | Glove- friendly touchscreen |
Certifications/Compliance | CE / TUV |
Optical Design | Double Beam |
Photometric Repeatability | ±0.001A at 1A measured at 1.0A at 546 nm |
Interface | Glove friendly touch-screen |
Weight (Metric) | 7.5 kg |
Wavelength Data Interval | 0.2 nm, 0.5 nm, 1 nm, 2 nm, 5 nm |
Display | 7 in. High Definition Color Touchscreen, Fixed, 800 x 1280 pixels |